Features
- Small size. Flush diaphragm type.
- Most suitable for the measurement of high response impulsive pressures.
- Covering applications for high viscosity pressure media.
- Accuracy class: 0.5% RO.
Model and Capacity / Frequency response / etc. (unit : mm)
|
|||
Model
|
Capacity
|
Natural frequency
|
Weight
|
HVF-2MPA
|
2MPa(20.39kgf/cm2)
|
71kHz
|
38g
|
HVF-5MPA
|
5MPa(50.99kgf/cm2)
|
110kHz
|
38g
|
HVF-10MPA
|
10MPa(102.0kgf/cm2)
|
150kHz
|
38g
|
HVF-20MPA
|
20MPa(203.9kgf/cm2)
|
210kHz
|
38g
|
HVF-50MPA
|
50MPa(509.9kgf/cm2)
|
320kHz
|
38g
|
- * The weight indicated in the tables of this data sheet does not include the weight of relay cables.
- * The numerical vaalues of the natural frequency indicated in this data sheet are the calculated values of the independent single elastic substance. The pressure response is dependent on features of the pressure media and so on.
Specifications
Safe Overload
120%RC
Rated Output
1.5mV/V±20%
Nonlinearity
0.5%RO
Hysteresis
0.5%RO
Repeatability
0.3%RO
Excitation Voltage
2V (or less)
Safe Excitation Voltage
3V
Input Rsistance
120Ω
Output Rsistance
120Ω
Compensated Temp.Range
0 to 50℃
Safe Temp.Range
-10 to 60℃
Temp.Effect on Zero
0.08%RO/℃
Temp.Effect on Output
0.05%/℃
Cable
Φ4mm-4wire shielded cable, length : 0.3m
Connector
Jack / PRC03-32A10-7F
Attached cable
L-A-5 (Refer to transducer connections)
Safe Overload
120%RC
Rated Output
1.5mV/V±20%
Nonlinearity
0.5%RO
Hysteresis
0.5%RO
Repeatability
0.3%RO
Excitation Voltage
2V (or less)
Safe Excitation Voltage
3V
Input Rsistance
120Ω
Output Rsistance
120Ω
Compensated Temp.Range
0 to 50℃
Safe Temp.Range
-10 to 60℃
Temp.Effect on Zero
0.08%RO/℃
Temp.Effect on Output
0.05%/℃
Cable
Φ4mm-4wire shielded cable, length : 0.3m
Connector
Jack / PRC03-32A10-7F
Attached cable
L-A-5 (Refer to transducer connections)