Silo filling level regulation by means of one limit switch


http://www.intl-sensor.com    Time:2008/6/19 17:50:17    Count : 2993 times

Filling of tanks is normally controlled by the signals of one upper and one lower limit switch (capacitive proximity switch). Installation of a second sensor is not required when a Proxitron sensor with integrated time delay is used. If the filling level falls below the desired value, a programmable delay between 1 s and 10 min. starts. Only after this time filling process starts until reaching the sensor level. Another advantage is a reduced filling frequency. This principle also works vice versa, using the lower limit value only.