Image | Main | Desc | Download |
---|---|---|---|
VTI SCA3100 | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output Lead-free Dual Flat Lead (DFL) package: | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output Lead-free Dual Flat Lead (DFL) package: | |
VTI SCA2120 | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output | |
VTI SCA2110 | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output Lead-free Dual Flat Lead (DFL) package: | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output Lead-free Dual Flat Lead (DFL) package: | |
VTI SCA2100 | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output | |
VTI SCA1000/1020 | 2-axis measurement; X-Y measurement and Z-Y measurement Measuring range ±1.7g,±4g Interchangeable with SCA610/620 SPI compatible digital output Internal temperature sensor, accessible via SPI Qualified according to AEC Q-100 | 2-axis measurement; X-Y measurement and Z-Y measurement Measuring range ±1.7g,±4g Interchangeable with SCA610/620 SPI compatible digital output Internal temperature sensor, accessible via SPI Qualified according to AEC Q-100 | |
VTI SCA830 | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output | |
VTI SCA820 | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output | |
VTI SCA810 | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output | ±2 g measurement range (to be extended to cover ±0.5g up to ±6.0g) Zero point accuracy over temperature ±70mg to ±100mg 3.3V supply Offset and sensitivity calibration Temperature offset compensation Same mechanical design and digital output | |
VTI SCA610 | Measuring range ±1g... ±3g Fully leadfree component and compliant with lead free processes Qualified according to AEC Q-100 | Measuring range ±1g... ±3g Fully leadfree component and compliant with lead free processes Qualified according to AEC Q-100 | |
VTI SCA620 | Measuring range ±1.7g and ±12g Based on new sensing element and custom ASIC with analogue output signal (0 to 5 Volts). Pre-moulded package, closed with a lid PIN compatible to SCA610 Series Fully leadfree component and compliant with lead free processes Qualified according to AEC Q-100 | Measuring range ±1.7g and ±12g Based on new sensing element and custom ASIC with analogue output signal (0 to 5 Volts). Pre-moulded package, closed with a lid PIN compatible to SCA610 Series Fully leadfree component and compliant with lead free processes Qualified according to AEC Q-100 | |
PCB 352A21 | Miniature, lightweight (0.6 gm) ceramic shear ICP® accel., 10 mV/g, 1 to 10k Hz, titanium hsg, 10-ft detachable cable Sensitivity: (±15%) 10 mV/g (1.0 mV/(m/s²)) Measurement Range: ±500 g pk (±4900 m/s² pk) Broadband Resolution: (1 to 10000 Hz) 0.002 g rms (0.02 m/s² rms) Frequency Range: (±5%) 1.0 to 10000 Hz Mounting: Adhesive Weight: 0.02 oz (0.6 gm) | Miniature, lightweight (0.6 gm) ceramic shear ICP® accel., 10 mV/g, 1 to 10k Hz, titanium hsg, 10-ft detachable cable Sensitivity: (±15%) 10 mV/g (1.0 mV/(m/s²)) Measurement Range: ±500 g pk (±4900 m/s² pk) Broadband Resolution: (1 to 10000 Hz) 0.002 g rms (0.02 m/s² rms) Frequency Range: (±5%) 1.0 to 10000 Hz Mounting: Adhesive Weight: 0.02 oz (0.6 gm) | |
PCB 353B01 | General purpose, quartz shear ICP® accel., 20 mV/g, 1 to 7k Hz, 10-32 side conn. Sensitivity: (±5%) 20 mV/g (2.04 mV/(m/s²)) Measurement Range: ±250 g pk (±2453 m/s² pk) Broadband Resolution: (1 to 10000 Hz) 0.005 g rms (0.05 m/s² rms) Frequency Range: (±5%) 1 to 7000 Hz Weight: 0.35 oz (10 gm) | General purpose, quartz shear ICP® accel., 20 mV/g, 1 to 7k Hz, 10-32 side conn. Sensitivity: (±5%) 20 mV/g (2.04 mV/(m/s²)) Measurement Range: ±250 g pk (±2453 m/s² pk) Broadband Resolution: (1 to 10000 Hz) 0.005 g rms (0.05 m/s² rms) Frequency Range: (±5%) 1 to 7000 Hz Weight: 0.35 oz (10 gm) | |
PCB 356B40 | Triaxial ICP® seat pad accel., 100 mV/g, 0.5 to 1000 Hz, 5-ft integral cable, conforms to ISO 10326-1 Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²)) Measurement Range: ±10 g pk (±98 m/s² pk) Broadband Resolution: (1 to 10000 Hz) 0.0002 g rms (0.002 m/s² rms) Frequency Range: (±5%) 0.5 to 1000 Hz Electrical Connector: Integral Cable Weight: 9.6 oz (272 gm) | Triaxial ICP® seat pad accel., 100 mV/g, 0.5 to 1000 Hz, 5-ft integral cable, conforms to ISO 10326-1 Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²)) Measurement Range: ±10 g pk (±98 m/s² pk) Broadband Resolution: (1 to 10000 Hz) 0.0002 g rms (0.002 m/s² rms) Frequency Range: (±5%) 0.5 to 1000 Hz Electrical Connector: Integral Cable Weight: 9.6 oz (272 gm) | |
PCB 356A02 | Triaxial, general purpose, ceramic shear ICP® accel., 10 mV/g, 1 to 5k Hz, 14 mm cube size, 4-pin conn. Sensitivity: (±10%) 10 mV/g (1.02 mV/(m/s²)) Measurement Range: ±500 g pk (±4900 m/s² pk) Broadband Resolution: (1 to 10000 Hz) 0.0005 g rms (0.005 m/s² rms) Frequency Range: (±5%) 1 to 5000 Hz Electrical Connector: 1/4-28 4-Pin Weight: 0.37 oz (10.5 gm) | Triaxial, general purpose, ceramic shear ICP® accel., 10 mV/g, 1 to 5k Hz, 14 mm cube size, 4-pin conn. Sensitivity: (±10%) 10 mV/g (1.02 mV/(m/s²)) Measurement Range: ±500 g pk (±4900 m/s² pk) Broadband Resolution: (1 to 10000 Hz) 0.0005 g rms (0.005 m/s² rms) Frequency Range: (±5%) 1 to 5000 Hz Electrical Connector: 1/4-28 4-Pin Weight: 0.37 oz (10.5 gm) | |
PCB 350A13 | Shock, quartz-shear, ICP® accel., 0.5 mV/g, 10k g range, LP filter, 10-32 top conn. Sensitivity: (±15%) 0.5 mV/g (0.051 mV/(m/s²)) Measurement Range: ±10000 g pk (±98000 m/s² pk) Frequency Range: (±10%) 0.4 to 7500 Hz Weight: 0.63 oz (17.9 gm) | Shock, quartz-shear, ICP® accel., 0.5 mV/g, 10k g range, LP filter, 10-32 top conn. Sensitivity: (±15%) 0.5 mV/g (0.051 mV/(m/s²)) Measurement Range: ±10000 g pk (±98000 m/s² pk) Frequency Range: (±10%) 0.4 to 7500 Hz Weight: 0.63 oz (17.9 gm) |
count34 every page 15 1/3page | first page prev page next page last page |