Image | Main | Desc | Download |
---|---|---|---|
U.S. real-time analysis of sound level meter LDI | ANSI / IEC Type 1 sound level meter-1 / 3 octave real-time analysis or FFT analysis Real-time filtering: 1 / 1 octave (16 hz to 16kHz) 1 / 3 octave (12.5 Hz to 20kHz) 400-FFT (1 Hz to 20 kHz) can be measured LEQ, SEL, Min, Max, Peak, the value A , C, Flat weighting Detector mode: slow, fast pulse | ANSI / IEC Type 1 sound level meter-1 / 3 octave real-time analysis or FFT analysis Real-time filtering: 1 / 1 octave (16 hz to 16kHz) 1 / 3 octave (12.5 Hz to 20kHz) 400-FFT (1 Hz to 20 kHz) can be measured LEQ, SEL, Min, Max, Peak, the value A , C, Flat weighting Detector mode: slow, fast pulse | |
U.S. analysis of environmental noise sound level meter LDI | Dynamic range: 120 dB Real-time analysis: 1 / 1, 1 / 3 octave record digital audio playback Internal memory: 1 GB | Dynamic range: 120 dB Real-time analysis: 1 / 1, 1 / 3 octave record digital audio playback Internal memory: 1 GB | |
Magnetic sensors sense SEN-S65 | Main features: Low Power: 3 VDC when the current of less than 500 μ A Small Size: 6.3 × 2.3 × 2.2mm The scope of the magnetic field measurements: ± 1100 μ T (± 11Gauss) High Resolution: 0.015 μ T (0.00015Gauss) Very few external components: 11096 ASIC and two each sensor resistance Parameters: Coil voltage: 2.0V Coil breakdown voltage: 200 V Bear the greatest current: 50 A Operating temperature: -55 ℃ ~ 140 ℃ | Main features: Low Power: 3 VDC when the current of less than 500 μ A Small Size: 6.3 × 2.3 × 2.2mm The scope of the magnetic field measurements: ± 1100 μ T (± 11Gauss) High Resolution: 0.015 μ T (0.00015Gauss) Very few external components: 11096 ASIC and two each sensor resistance Parameters: Coil voltage: 2.0V Coil breakdown voltage: 200 V Bear the greatest current: 50 A Operating temperature: -55 ℃ ~ 140 ℃ | |
LIPS 101 Stand Alone Linear Position Sensor | Non-contacting inductive technology to eliminate wear Travel set to customer's requirement Compact and self-contained High durability and reliability High accuracy and stability Sealing to IP65/IP67 as required | ||
Process Sense™ NDIR Analyzer | Fast response enables real-time chamber clean endpoint detection - lower Cost of Ownership, Reduces chamber erosion from over cleaning - extending the life of the chamber, Optimizing chamber clean time increases tool availability, Reduced over-clean lowers particulate generation for improved yield, Permanent calibration unaffected by process conditions, Complete upgrade kits available for AMAT CVD tools. |
count5 every page 15 1/1page | first page prev page next page last page |