Honsberg FW1
principle control
electr. data reed switch n.o.
230 V AC 0.5A 50 VA
basic data PN 10-100 , tmax=90°C
connection G1/4 - G1 female thread plastic / brass
range 1-11 l/min H2O
principle control
electr. data reed switch n.o.
230 V AC 0.5A 50 VA
basic data PN 10-100 , tmax=90°C
connection G1/4 - G1 female thread plastic / brass
range 1-11 l/min H2O

Honsberg FW3
principle control
electr. data reed switch n.o.
230 V AC 0.5A 50 VA
basic data PN 100 , tmax=90°C
connection G1/4 female thread brass
range 0.4-2.5 l/min H2O
principle control
electr. data reed switch n.o.
230 V AC 0.5A 50 VA
basic data PN 100 , tmax=90°C
connection G1/4 female thread brass
range 0.4-2.5 l/min H2O

Honsberg HD1K
principle control • option indicate
electr. data reed switch change over
250 V AC 1.5A 50 VA
basic data PN 200 , tmax=120°C
connection G1/4 - G1 female thread brass / stainless steel
range 0.5-60 l/min H2O
switch head ATEX switch head ATEX
I M1 EEx ia I
II 1G EEx ia IIC T4
II 1D EEx iaD 20 T135
also as omni-HD1K local electronic unit
2xNPN and PNP switch point
4(0)...20mA ouput
graphical LCD display with flashing LED
program ring
principle control • option indicate
electr. data reed switch change over
250 V AC 1.5A 50 VA
basic data PN 200 , tmax=120°C
connection G1/4 - G1 female thread brass / stainless steel
range 0.5-60 l/min H2O
switch head ATEX switch head ATEX
I M1 EEx ia I
II 1G EEx ia IIC T4
II 1D EEx iaD 20 T135
also as omni-HD1K local electronic unit
2xNPN and PNP switch point
4(0)...20mA ouput
graphical LCD display with flashing LED
program ring

Honsberg GKL
principle local measure • option control
basic data PN 15 , tmax=60°C
connection Rp1 - Rp2 female thread cast iron
range 100-6400 l/h H2O
1.25-250 Nm³/h air
principle local measure • option control
basic data PN 15 , tmax=60°C
connection Rp1 - Rp2 female thread cast iron
range 100-6400 l/h H2O
1.25-250 Nm³/h air

Honsberg GR-065
principle local measure
basic data PN 10 , tmax=90°C
connection NPT1/8" female thread stainless steel
range 0.2-1305 cm³/min H2O
2-43340 Ncm³/min air
principle local measure
basic data PN 10 , tmax=90°C
connection NPT1/8" female thread stainless steel
range 0.2-1305 cm³/min H2O
2-43340 Ncm³/min air

Honsberg UK-040
principle local measure • adjust
basic data PN 6 , tmax=65°C
connection NPT1/8" female thread brass / stainless steel
range 6-220 l/h H2O
0.1-100 Nl/min air
principle local measure • adjust
basic data PN 6 , tmax=65°C
connection NPT1/8" female thread brass / stainless steel
range 6-220 l/h H2O
0.1-100 Nl/min air

Honsberg UR3K
principle control
electr. data reed switch n.o.
230 V AC 1A 50 VA
basic data PN 16-25 , tmax=110°C
connection
range G3/8 - G2 female thread brass / stainless steel
3-69 l/min H2O
connection
range DN15-80 welding/soldering socket brass/stainless steel
8.5-248 l/min H2O
connection
range DN10-40 solder fitting copper (special application)
4.5-46 l/min H2O
principle control
electr. data reed switch n.o.
230 V AC 1A 50 VA
basic data PN 16-25 , tmax=110°C
connection
range G3/8 - G2 female thread brass / stainless steel
3-69 l/min H2O
connection
range DN15-80 welding/soldering socket brass/stainless steel
8.5-248 l/min H2O
connection
range DN10-40 solder fitting copper (special application)
4.5-46 l/min H2O

Honsberg CM2K
principle control
electr. data micro switch change over
250 V AC 5A
basic data PN 25 , tmax=110°C
connection DN25-200 R1 " male thread socket brass / stainless steel
range 0.5-71 m³/h H2O
principle control
electr. data micro switch change over
250 V AC 5A
basic data PN 25 , tmax=110°C
connection DN25-200 R1 " male thread socket brass / stainless steel
range 0.5-71 m³/h H2O

Honsberg WO1
principle indicate
basic data PN 16 , tmax=100°C
connection G1/4 - G1 1/2 female thread brass / stainless steel
principle indicate
basic data PN 16 , tmax=100°C
connection G1/4 - G1 1/2 female thread brass / stainless steel

Germany honsbreg ultrasound, float level switch
Technical data:
Maglev as the medium of the location change, trigger alarm body movements
Installation of principle: Float, horizontal, vertical, ultrasonic
Applications: cans, shaft, ultra-flow, low-level protection of non-contact protection, multi-point control DN: 1 / 4 ~ 1 "
Link: Support thread
Operating temperature: 120 ℃
Signal: Contact signal
Adjustable: yes
Materials: copper, stainless steel, plastic
Installation: Vertical
Media Measurement: liquid or solid
Technical data:
Maglev as the medium of the location change, trigger alarm body movements
Installation of principle: Float, horizontal, vertical, ultrasonic
Applications: cans, shaft, ultra-flow, low-level protection of non-contact protection, multi-point control DN: 1 / 4 ~ 1 "
Link: Support thread
Operating temperature: 120 ℃
Signal: Contact signal
Adjustable: yes
Materials: copper, stainless steel, plastic
Installation: Vertical
Media Measurement: liquid or solid

The U.S. HMR3000 Honeywell digital compass module
HMR3000 is an electronic compass, to direct the direction, slope and rotation information.

Direction accuracy of 0.5 degrees, a resolution of 0.1 degrees. Slope of the range of + / -40 degrees. RS232/485 NMEA output mode refresh frequency of 20 Hz.
HMR3000 is an electronic compass, to direct the direction, slope and rotation information.

Direction accuracy of 0.5 degrees, a resolution of 0.1 degrees. Slope of the range of + / -40 degrees. RS232/485 NMEA output mode refresh frequency of 20 Hz.

Germany Heidenhain angle encoder RON786
Large-diameter hollow shaft D = 60mm
Measuring step 0.0001 °
System accuracy ± 2 "
Lines 18000/36000
Machinery allowed to speed ≤ 1000 rpm
Incremental signal 1 Vpp
Large-diameter hollow shaft D = 60mm
Measuring step 0.0001 °
System accuracy ± 2 "
Lines 18000/36000
Machinery allowed to speed ≤ 1000 rpm
Incremental signal 1 Vpp

Germany Heidenhain angle encoder series ERN100
Large-diameter hollow shaft: 20 mm, 25mm, 38mm, 50mm
Shell foreign economy: 87 mm
Encoder stator coupling the natural frequency: ≥ 1000 Hz
Machinery allowed to speed: 6000 rpm (D ≤ 30 mm), 4000rpm (D> 30mm)
Line: 1000-5000
Large-diameter hollow shaft: 20 mm, 25mm, 38mm, 50mm
Shell foreign economy: 87 mm
Encoder stator coupling the natural frequency: ≥ 1000 Hz
Machinery allowed to speed: 6000 rpm (D ≤ 30 mm), 4000rpm (D> 30mm)
Line: 1000-5000

Germany FSG angle sensor
Rotation :0-90 ° ,0-360 °Rotation :0-90 ° ,0-360 °

Germany OPTEK - ASD cell density sensor
Product Overview
Real-time monitoring of fermentation tank with cell growth, protein to maximize output. Used to measure high concentrations of bacteria, yeast cells and a low concentration of animal cells. Fermentation for large irrigation, the should -

Technical parameters
Can be heated (130 ℃)
Measuring range: 4.0CU, 200OD, 500ppm, 20% solid (FTU, EBC)
Product Overview
Real-time monitoring of fermentation tank with cell growth, protein to maximize output. Used to measure high concentrations of bacteria, yeast cells and a low concentration of animal cells. Fermentation for large irrigation, the should -

Technical parameters
Can be heated (130 ℃)
Measuring range: 4.0CU, 200OD, 500ppm, 20% solid (FTU, EBC)
count60 every page 15 2/4page   first page   prev page   next page   last page
INTL-SENSOR CopyRight
© Copyright By WWW.INTL-SENSOR.COM All Right
tel:86 010-67152280/67114885/67124125
E-mail:pcb@intl-sensor.com
京ICP备07000717号
京公网安备110101000113号